www.rosemount.com
¢00825-0200-4697[¤
Quick Installation Guide
00825-0100-4697, Rev DB
September 2011
Rosemount 848T
Start
End
Step 1: Mount the Transmitter
Step 2: Wire and Apply Power
Step 3: Verify the Tag
Step 4: Verify Transmitter Configuration
Product Certifications
EC Declaration of Conformity
Rosemount 848T FOUNDATION
Fieldbus High Density
Temperature Transmitter
Vedere la pagina 0
1 2 3 4 5 6 ... 19 20

Sommario

Pagina 1 - ¢00825-0200-4697[¤

www.rosemount.com¢00825-0200-4697[¤Quick Installation Guide00825-0100-4697, Rev DBSeptember 2011Rosemount 848TStartEndStep 1: Mount the TransmitterSte

Pagina 2 - IMPORTANT NOTICE

Quick Installation Guide00825-0100-4697, Rev DBSeptember 2011Rosemount 848T10PRODUCT CERTIFICATIONSNorth American ApprovalsFactory Mutual (FM) Approva

Pagina 3 - STEP 1: MOUNT THE TRANSMITTER

Quick Installation Guide00825-0100-4697, Rev DBSeptember 2011Rosemount 848T11N5 Dust Ignition-Proof For use in Class II, III, Division 1, Groups E, F,

Pagina 4 - STEP 2: WIRE AND APPLY POWER

Quick Installation Guide00825-0100-4697, Rev DBSeptember 2011Rosemount 848T12Suitable for use in Class I, Division 2, Groups A, B, C, D. when installe

Pagina 5

Quick Installation Guide00825-0100-4697, Rev DBSeptember 2011Rosemount 848T13European ApprovalsATEX ApprovalsI1 Intrinsic SafetyCertification Number:

Pagina 6

Quick Installation Guide00825-0100-4697, Rev DBSeptember 2011Rosemount 848T14NE ATEX TYPE ‘n’ APPROVALCertification Number: BASEFFA09ATEX0095XATEX Mar

Pagina 7

Quick Installation Guide00825-0100-4697, Rev DBSeptember 2011Rosemount 848T15SPECIAL CONDITIONS FOR SAFE USE (X):1. The component must be housed in a

Pagina 8 - STEP 3: VERIFY THE TAG

Quick Installation Guide00825-0100-4697, Rev DBSeptember 2011Rosemount 848T16IG IECEx FISCOCertificate No.: IECExBAS09.0030XEx ia IIC T4 (Tamb = – 50

Pagina 9

Quick Installation Guide00825-0100-4697, Rev DBSeptember 2011Rosemount 848T17NOTE:NJ is valid with S001 and S002 Input TypesSPECIAL CONDITIONS OF SAFE

Pagina 10 - PRODUCT CERTIFICATIONS

Quick Installation Guide00825-0100-4697, Rev DBSeptember 2011Rosemount 848T18Figure 9. EC Declaration of Conformity for 848T Temperature Transmitter

Pagina 11 - Rosemount 848T

Quick Installation Guide00825-0100-4697, Rev DBSeptember 2011Rosemount 848T19

Pagina 12

Quick Installation Guide00825-0100-4697, Rev DBSeptember 2011Rosemount 848T2© 2011 Rosemount Inc. All rights reserved. All marks property of owner.IM

Pagina 13

Quick Installation Guide00825-0100-4697, Rev DBSeptember 2011Rosemount 848T20

Pagina 14

Quick Installation Guide00825-0100-4697, Rev DBSeptember 2011Rosemount 848T3STEP 1: MOUNT THE TRANSMITTERMount to a DIN Rail Without a Junction BoxMou

Pagina 15

Quick Installation Guide00825-0100-4697, Rev DBSeptember 2011Rosemount 848T4STEP 2: WIRE AND APPLY POWERPower is polarity insensitive, allowing the us

Pagina 16

Quick Installation Guide00825-0100-4697, Rev DBSeptember 2011Rosemount 848T5STEP 2 CONTINUED...Sensor Wiring and Power Supply• Compatible with eight i

Pagina 17

Quick Installation Guide00825-0100-4697, Rev DBSeptember 2011Rosemount 848T6STEP 2 CONTINUED...Typical Configuration for FOUNDATION fieldbus Networkin

Pagina 18

Quick Installation Guide00825-0100-4697, Rev DBSeptember 2011Rosemount 848T7STEP 2 CONTINUED...Option 2:1. Connect sensor wiring shield(s) to the tran

Pagina 19

Quick Installation Guide00825-0100-4697, Rev DBSeptember 2011Rosemount 848T8STEP 3: VERIFY THE TAGSTEP 4: VERIFY TRANSMITTER CONFIGURATIONEach FOUNDAT

Pagina 20

Quick Installation Guide00825-0100-4697, Rev DBSeptember 2011Rosemount 848T9STEP 4 CONTINUED...NOTETo make changes to the AI block, the BLOCK_MODE (TA